A DC fan is not necessarily a fixed-speed device. Depending on how many wires it has, it can be throttled, monitored, or both. The wire count is the first thing to confirm in any fan specification — here is what each configuration does.
Two-wire: power only
The simplest fan: positive and negative. Speed follows voltage, so the only way to slow it down is to lower the supply voltage or insert a series resistor / thermistor. Two-wire fans are right for cost-driven products with a predictable thermal load, such as adapters and small appliances.
Three-wire: add a tacho (FG)
The third wire is a speed-feedback signal, usually called FG (frequency generator) or tacho. It typically outputs 2 pulses per revolution as an open-collector square wave — so a fan at 3,000 RPM produces a 100 Hz signal your MCU can count. What you get:
- Verification that the fan is actually spinning (a stalled fan reports zero)
- Trend monitoring — bearing wear shows up as RPM drift long before failure
- Closed-loop verification of voltage-based speed control
A tacho tells you the speed but cannot change it. For that you need PWM.
Four-wire: PWM speed control
In the four-wire configuration — the same one used by standard PC and server fans — the fan is fed full voltage on two wires and receives a PWM signal on a dedicated control wire. Key parameters to align with your design:
- Duty cycle range: typically 20–100%; below the minimum duty the fan may stop, so define your floor
- PWM frequency: 21–28 kHz is the industry standard — above audible range, so the fan never whines
- Logic level: 3.3 V or 5 V logic, open-collector or push-pull — confirm with the fan maker
- Zero-RPM option: some of our models support a "stop at 0% duty" mode for silent standby
PWM control in the fan (rather than voltage control in your circuit) keeps the fan's internal driver at optimal efficiency and gives a clean, linear speed curve — which is why it is the default choice for EV chargers, energy-storage systems and telecom power.
RD: the alarm variant
An RD (rotation detect) signal is a status line rather than a pulse train: it holds one level while the fan rotates and flips when the fan stalls or drops below a threshold speed. Where FG is for logging and trend analysis, RD is for protection circuits — trigger a shutdown or an alarm relay when RD changes. Many of our industrial models can supply RD instead of FG on request.
| Configuration | Wires | Control | Monitoring | Typical use |
|---|---|---|---|---|
| Basic | 2 | Voltage only | None | Adapters, appliances |
| Tacho | 3 | Voltage only | RPM (FG) | Servers, medical, monitoring systems |
| PWM | 4 | PWM duty | Optional FG/RD | EV chargers, energy storage, telecom |
Wiring and connector notes
We build fans with the common harness standards — JST XH2.54 / PH2.0 / VH3.96 and Molex 2510 — and match the wire-color conventions your system already uses. When requesting a quote, send your connector part number and wire-definition table; if you don't have one, a photo of your current fan's plug is enough for us to match it.
Rule of thumb: if the product has a user-facing noise target or a fan-failure alarm requirement, specify PWM + FG from the start — retrofitting signal wires into a two-wire design later costs far more.